P-660R/H-D Series User’s Guide
Chapter 31 Firmware and Configuration File Maintenance 280
31.2.6 Backup Configuration Using TFTP
The Prestige supports the up/downloading of the firmware and the configuration file using
TFTP (Trivial File Transfer Protocol) over LAN. Although TFTP should work over WAN as
well, it is not recommended.
To use TFTP, your computer must have both telnet and TFTP clients. To backup the
configuration file, follow the procedure shown next.
1 Use telnet from your computer to connect to the Prestige and log in. Because TFTP does
not have any security checks, the Prestige records the IP address of the telnet client and
accepts TFTP requests only from this address.
2 Put the SMT in command interpreter (CI) mode by entering 8 in Menu 24 - System
Maintenance.
3 Enter command “
sys stdio 0” to disable the SMT timeout, so the TFTP transfer will
not be interrupted. Enter command “
sys stdio 5” to restore the five-minute SMT
timeout (default) when the file transfer is complete.
4 Launch the TFTP client on your computer and connect to the Prestige. Set the transfer
mode to binary before starting data transfer.
5 Use the TFTP client (see the example below) to transfer files between the Prestige and the
computer. The file name for the configuration file is “
rom-0” (rom-zero, not capital o).
Note that the telnet connection must be active and the SMT in CI mode before and during the
TFTP transfer. For details on TFTP commands (see following example), please consult the
documentation of your TFTP client program. For UNIX, use “
get” to transfer from the
Prestige to the computer and “binary” to set binary transfer mode.
31.2.7 TFTP Command Example
The following is an example TFTP command:
tftp [-i] host get rom-0 config.rom
where “i” specifies binary image transfer mode (use this mode when transferring binary files),
host” is the Prestige IP address, “get” transfers the file source on the Prestige (rom-0,
name of the configuration file on the Prestige) to the file destination on the computer and
renames it config.rom.
31.2.8 GUI-based TFTP Clients
The following table describes some of the fields that you may see in GUI-based TFTP clients.