Chapter 3 VLC Troubleshooting
VLC1324G User’s Guide
35
Figure 10 Example Xmodem Upload
10 After a successful firmware upload, the line card restarts. The console port speed
automatically changes back to 9600 bps when the line card restarts.
Bootbase Version: V1.00 | 03/23/2005 16:10:06
FLASH: AMD 32M
Hardware Version:
Serial Number:
RAM: Size = 133120 Kbytes
ZyNOS Version: V3.90(AYL.0)b5 | 1/01/2008 20:50:26
Press any key to enter debug mode within 3 seconds.
...........
Enter Debug Mode
atba5
Now, console speed will be changed to 115200 bps
OK
atur
Starting XMODEM upload (CRC mode)....
CCCCCCCC
Total 2003968 bytes received.
Erasing...............................
...........................................................................
...........................................................................
...........................................................................
...........................................................................
...........................................................................
...........................................................................
.........
OK
System Reboot...
Console speed will be changed to 9600 bps
Type the firmware file's
location, or click Browse to
search for it.
Choose the 1K Xmodem
protocol.
Then click Send.