Chapter 44 Alarm Commands
IES-612-51 User’s Guide
277
44.2.1 Alarm Show Command Example
The following example shows the results of using this command.
The source is where the alarm originated. This is either a DSL port number, one of the
Ethernet ports (enet 1 or 2), or “eqpt” for the system itself.
alarm cutoff This command cancels an alarm. This stops the
sending of the alarm signal current. This is useful in
stopping an alarm if you have the alarm output
connector pins connected to a visible or audible
alarm. The alarm entry remains in the system.
M/~
alarm clear This command erases the clearable alarm entries. M/H
Table 98 alarm Commands (continued)
COMMAND DESCRIPTION P
ras> alarm show
[current alarm list]
no alarm condition severity timestamp source
------ ------ -------------------- -------- -------------- -------
1 eqpt +fan_err critical 09/19 12:49:10 eqpt 1
2 eqpt +fan_err critical 09/19 12:49:10 eqpt 3
3 eqpt +fan_err critical 09/19 12:49:10 eqpt 2