ZyXEL Confidential
404XD3C0.docx
161/181
kbps and Scheduler = Priority-Based
(2) In eWCÆBW MGMTÆClass Setup, Adds two sub-classes under WAN1 root class.
Where WAN1-1 : Bandwidth Budget = 200, Priority = 7(higher than WAN1-2), and
“Borrow bandwidth from parent class” is selected; WAN1-2 : Bandwidth Budget = 500,
Priority = 1, “Borrow bandwidth from parent class” is also selected.
(3) First generates traffic that satisfies WAN1-2 class, users will find WAN1-2 borrow
the whole available bandwidth from parent, and the traffic is bound at about 1500kbps.
(4) Then generates traffic that satisfies WAN1-1 class. Users will find WAN1-1 can
not borrow bandwidth from parent class and bandwidth is bound at about 200kbps even
though WAN1-1 has higher priority than WAN1-2.
8. [BUG FIX]
Symptom: In eWCÆMAINTENANCEÆGeneral, set a number which is bigger than
1000 for Administrator Inactivity Timer. The label string 'Administrator Inactivity
Timer' will disappear.
Condition:
(1) Go to eWCÆMAINTENANCEÆGeneral, set a number which is bigger than 1000
for Administrator Inactivity Timer.
(2) Click 'Apply'.
(3) The label string 'Administrator Inactivity Timer' will disappear.
9. [BUG FIX]
Symptom: ZyWALL ping sometimes fails.
Condition:
(1) Turn on Firewall.
(2) Go to SMT 24.8
(3) Ping to exist host, but it sometimes fails.
10. [BUG FIX]
Symptom: In SMT 3.2, the subnet of ZyWALL LAN IP can be different from the
subnet of DHCP client ip and ZyWALL LAN IP can be set within DHCP Client IP pool
range.
Condition:
First case:
(1) Go to SMT 3.2
(2) Set DHCP client IP Starting address to be 192.168.2.3
(3) Set LAN IP Address to be 192.168.1.1, then confirm to save.
(4) These setting can be saved and no error message.
Second case:
(1) In SMT 3.2, set DHCP client ip Starting address to be 192.168.1.3
(2) Set Size of Client IP Pool to be 10
(3) Set LAN IP Address to be 192.168.1.3, then confirm to save.
(4) These setting can be saved and no error message.
11. [BUG FIX]
Symptom: Remote access control cannot work properly.
Condition:
(1) Turn on bridge mode
(2) Configure telnet server access control from WAN only by SMT 24.11
(3) Telnet to device via WAN side
Comentários a estes Manuais