configuring them according to the targeted operating systems. They are described
for Windows XP as well as for the Linux and FreeBSD systems.
Configuring a PLC Network Under Windows
Almost all the tools used for configuring HomePlug PLC devices have the same
functionalities for the configuration of HomePlug chip parameters. As we have seen
in Chapter 7, HomePlug chips mainly originate from the Intellon manufacturer.
They are used for reading a number of values stored on the quality of exchanges
between PLC devices. The PLC network is configured and optimized using these val-
ues.
Among the HomePlug parameters that can be configured, let’s mention the fol-
lowing ones in particular:
The NEK (network encryption key) used for securing data exchanges in the
same PLC local area network;
The DEK (default encryption key) used for configuring the NEK on all the
remote PLC devices scattered over the electrical network;
The PLC device transmission priority among four possible ones (CA0, CA1,
CA2, CA3) used for configuring some PLC devices like gateways to other net-
works, in particular Ethernet.
Table 9.1 summarizes the main parameters which can be read and presented to
the PLC network user with HomePlug configuration tools.
Estimating the PHY Data Rate of Communications Between PLC Devices
The various PLC devices store the instantaneous value of the “bytes in 40 symbols” parame-
ters exchanged by the devices in the HomePlug chip. This value is used for estimating
the PHY data rate (at the physical layer level) between PLC devices, as we have seen in
Chapter 3.
The maximum PHY data rate corresponds to the number of data (or bits) ensuring the
best possible modulation coded with 40-symbol OFDM blocks of duration 8.4 μs.
This gives, for HomePlug 1.0 and Turbo:
HomePlug 1.0:
Datarate
PHMAXY
=
×
×
=
519 8
40 8 4
12 35714286
.
,/Mbit s
HomePlug Turbo:
Datarate
PHMAX
=
×
×
=
2 812 8
40 8 4
66 95238095
,
.
,/Mbit s
Still using the data mentioned in Chapter 3, the PHY data rate can be calculated
according to the values given by the HomePlug chip:
HomePlug 1.0:
Datarate
BYTES
PHY
in symbols
=
×+
588 38
481 42
14
588 38
40
481
519
42
×
Mbit s/
180 Configuration