108 Status Registers & Result Codes
Command bit dec hex Function and description Ref.
power on
64 40 Profile 2 as active settings after
power on
Z2
96 60 Profile 3 as active settings after
power on
Z3
128 80 *
Factory default as active settings
after power on
Z4
S16= dec hex Test status register +000
0 0 No test in progress &T0
1 1 Loop-back test in progress &T1
3 3 Local Digital Loop-back test in
process
&T3
6 6 Remote Digital Loop-back test
in process
&T6
7 7 Remote Digital Loop-back with
self-test in process
&T7
8 8 Analog Loop-back with self test
in progress
&T8
S17= bit dec hex Bit-mapped register +018
0 0 0 Disable secondary channel
(default)
*S0
4-1
0-30
0-1E
Set leased line transmit power
level from 0 to -15 dBm. (See
also S35b3) (Default *P9)
*Pn
5 0 0 Normal dial (Default) D
32 20 Reverse dial, go on-line in
answer mode.
DR
7,6
0 0 AT Commands set (Default) *I0
64 40 V.25bis command set *I1
128 80
Dumb mode (no command
*I2