Chapter 47 Diagnostic
IES-1248-51V User’s Guide
351
Received Firmware
Invalid!
WARN Someone attempted to upload a firmware file with a
wrong identity via FTP.
Received File <file>! INFO A file was uploaded to the IES-1248-51V by FTP.
<file> - received file’s name
THERMO OVER
TEMPERATURE: dev:<id>
threshold:<threshold>
(degree C)
value:<temp>(degree
C)!
WARN The temperature was too high at one of the
temperature sensors.
<id> -
0: sensor near the ADSL chipset
1: sensor near the CPU
2: thermal sensor chip itself
<threshold> - threshold temperature
<temp> - temperature when the entry was logged
THERMO OVER
TEMPERATURE released:
dev:<id>
threshold:<threshold>
(degree C)
value:<temp>(degree
C)!
INFO The temperature at one of the temperature sensors
has come back to normal.
<id>
0: sensor near the ADSL chipset
1: sensor near the CPU
2: thermal sensor chip itself
<threshold> - threshold temperature
<temp> - temperature when the entry was logged
THERMO OVER VOLTAGE:
nominal:<nominal>(mV)
value:<voltage> mV)!
WARN The voltage went outside of the accepted operating
range.
<nominal> - nominal voltage of the DC power
<voltage> - voltage of the DC power when logged
THERMO OVER VOLTAGE
released:
nominal:<nominal>(mV)
value:<voltage> (mV)!
INFO The voltage is back inside the accepted operating
range.
<nominal> - nominal voltage of the DC power
<voltage> - voltage of the DC power when logged
Table 123 Log Messages (continued)
LOG MESSAGE TYPE DESCRIPTION