Chapter 68 VoIP Commands
IES-1248-51V User’s Guide
547
68.4.2 diagnostic mlt show Command Example
The following example shows the result of the last test conducted on the line
connected to port 8.
68.4.3 voip diagnostic mlt relay set Command Example
The following example allows diagnostic testing (both directions) on port 8.
ras> voip diagnostic mlt show 8
Port 8: testing
Foreign AC Voltage Test Results
vTip = 0.0 Vrms
vRing = 0.0 Vrms
vDiff = 0.0 Vrms
Foreign DC Voltage Test Results
vTip = 0.0 Volts
vRing = 0.0 Volts
vDiff = 0.0 Volts
DC Loop Resistance Test Results
rLoop = 4390.2 Ohms
Three-Element Resistance Test Results
rTG = OPEN
rRG = OPEN
rTR = OPEN
No Three-Element Capacitance Test Results
Ringer Equivalence Numer Test Results
REN = 2147483647.2147483647
No Ringing Voltage Test Results
No Metering Voltage Test Results
ras>
ras> voip diagnostic mlt relay set 8 both
Comentários a estes Manuais